@article { author = {Ramezani Moghaddam, َAli and Lamehi, M and Rahighi, J}, title = {Design and Fabrication of the Helmholtz Coil for the Permanent Magnet Measurement}, journal = {Journal of Nuclear Science and Technology (JONSAT)}, volume = {37}, number = {4}, pages = {1-11}, year = {2017}, publisher = {Nuclear Science and Technology Research Institute}, issn = {1735-1871}, eissn = {2676-5861}, doi = {}, abstract = {The direction and magnitude of the magnetization of a permanent magnet has some deviation from the desired value after the manufacturing. This paper describes the physical and mechanical designs and finally the manufacturing process of a the Helmholtz coil for the first time in Iran in order to measure the permanent magnets magnetization for using in a planar undulator. The Helmholtz coil calibration has been discussed by using a current source and Hall probe with the necessary precision. The final precision for an easy-axis magnetization measurement is 0.03%, and accuracy is 0.015%. 160 permanent magnet blocks have been measured by the Helmholtz coil. The measurement results of the magnetization components are presented and results are used in fabrication of the first undulator at the ILSF.}, keywords = {Helmholtz Coil,Permanent Magnets,Magnetization Vector,Planar Undulator}, title_fa = {طراحی و ساخت پیچه‌ی هلمهولتز به منظور اندازه‌گیری آهنرباهای دائمی}, abstract_fa = {شدت و جهت بردار مغناطش آهنرباهای دائمی بعد از ساخت، به دلایل گوناگونی، از شدت و جهت مطلوبی که حین ساخت مورد نظر بوده است اختلاف خواهند داشت. در این مقاله، مراحل طراحی فیزیکی و مکانیکی و سپس ساخت پیچه‌­ی هلمهولتز برای اندازه­‌گیری شدت و جهت بردار مغناطش در آهنرباهای دائمی به منظور استفاده در ساخت یک آندولاتور تخت برای اولین بار در کشور ارائه شده است. کالیبراسیون پیچه‌ی هلمهولتز با منبع جریان و پروب هال با دقت لازم بحث شده است. دقت اندازه­‌گیری شدت بردار مغناطش در راستای محور آسایش آن در حدود 0.03%، و صحت اندازه­‌گیری 0.015% به دست آمده است. به کمک پیچه­‌ی هلمهولتز، تعداد حدود 160 آهنربای دائمی اندازه­‌گیری شده­‌اند. نتایج اندازه­‌گیری مؤلفه‌­های مختلف این آهنرباها ارائه، و از نتایج به دست آمده در ساخت اولین آندولاتور طرح چشمه­‌ی نور ایران استفاده شده است.}, keywords_fa = {Helmholtz Coil,Permanent Magnets,Magnetization Vector,Planar Undulator}, url = {https://jonsat.nstri.ir/article_131.html}, eprint = {https://jonsat.nstri.ir/article_131_7227f85a5de2ebd36565e2000cadd5a6.pdf} } @article { author = {Ziaeian, I and Sadat Kiai, S. M and Zebardast, M and Goosheh, A. R}, title = {Modification of the Stability Regions in Stretched Paul Ion Trap by Damping Force}, journal = {Journal of Nuclear Science and Technology (JONSAT)}, volume = {37}, number = {4}, pages = {12-17}, year = {2017}, publisher = {Nuclear Science and Technology Research Institute}, issn = {1735-1871}, eissn = {2676-5861}, doi = {}, abstract = {With the change of an ion trap geometrical shape, ring and end-cap electrodes, and also damping force effects, the first and second stability regions are studied in a stretched Paul ion trap. In this article, according to a new idea, we changed the trap geometry based on the change in distances between the ring electrode (2r˳) and end-cap electrodes (2z˳). For this purpose, the geometrical parameter n=(r˳/z˳)2 was introduced in our calculations. Also, for the damping effects, we entered a viscous damping factor (k) in the Mathieu equation. The set of differential equation governing the motion of the confined ion is considered, taking into account the effect of damping force and the ion trap geometry. The Mathieu type differential equations were solved using Runge-Kutta Verner fifth-order and sixth-order method (RKV56). Comparisons were made with the corresponding stability diagrams without considering the effects of damping force in an ideal ion trap . The numerical results showed that, for a given ion trap mode i.e., rf only mode, the damping force and the trap geometry played important roles in the relocation of the stability diagrams. The first and second stability regions in the presence of the damping force, according to trap’s geometry, are reported for the first time.}, keywords = {: Damping Force,Trap Geometry,Quadrupole Potential,Runge-Kutta Verner}, title_fa = {اصلاح نواحی پایداری در دام یونی کشیده‌ی پائول در حضور نیروی میراکننده}, abstract_fa = {با تغییر در شکل هندسی دام و تأثیر نیروی میراکننده، نواحی پایداری اول و دوم در دام چهارقطبی کشیده­ی پائول، بررسی شد. در این مقاله، منظور از تغییر در شکل هندسی دام، تغییر در فواصل بین الکترود حلقه (2r0) و الکترودهای کلاهک (2z0) است. برای این هدف،پارامتر2(z0/r0)=n  در محاسبات وارد شد. هم­‌چنین، تأثیر نیروی میراکننده، با وارد کردن ثابت میرایی k در معادله­‌ی ماتی­یو بررسی شد. دستگاه معادلات دیفرانسیل حاکم بر رفتار یون درون دام چهارقطبی با توجه به آثار هم­‌زمان نیروی میراکننده و هندسه­‌ی دام، در نظر گرفته شده است. این معادلات با استفاده از روش رونگه کوتای مرتبه‌­ی 5 و مرتبه­‌ی 6 ورنر (RKV56) به دقت محاسبه، و نواحی پایداری به دست آمده با نواحی پایداری در غیاب نیروی میراکننده در دام یونی ایده­‌آل (r02=2z02) مقایسه شده است. نتایج به دست آمده نشان می‌­دهند که در یک دام یونی rf، نیروی میرایی و شکل هندسی دام، نقش تعیین­کننده­ای در جابه‌جایی نواحی پایداری دارند. یادآوری می‌­شود که محاسبه­‌ی نواحی پایداری در حضور نیروی میراکننده با توجه به تغییر در فاصله­‌ی بین الکترودهای کلاهک با این روش برای اولین بار گزارش می­‌شود.}, keywords_fa = {: Damping Force,Trap Geometry,Quadrupole Potential,Runge-Kutta Verner}, url = {https://jonsat.nstri.ir/article_132.html}, eprint = {https://jonsat.nstri.ir/article_132_29cb2be868c8eeaec2a9be8e0411aea9.pdf} } @article { author = {Poorbaygi, H and Pourali, S and Mostajaboddavati, M and Bagheri, S}, title = {Design and Calibration of a Chair-Type Whole Body Counter}, journal = {Journal of Nuclear Science and Technology (JONSAT)}, volume = {37}, number = {4}, pages = {18-23}, year = {2017}, publisher = {Nuclear Science and Technology Research Institute}, issn = {1735-1871}, eissn = {2676-5861}, doi = {}, abstract = {A whole body counter is used for in vivo measurement of body radioactivity to access the internal exposure of radiation workers, as well as, the internal exposure of the public. The chair-type WBC is more suitable than the other geometry for rapid monitoring in radiation accidents. In this study, a transportable in vivo monitoring system with the chair-type geometry has been designed, and evaluation of the counting efficiency has been performed to calibrate the system effectively. The counter incorporates Nal (Tl) detectors (5cm dia.×5cm), housed in a collimator, and the chair is shielded using 2cm thick lead layers. For calculating the seat angle of the chair and collimator angle, a Bottle Mannkin Absorber (BOMAB) phantom model has been used. The counting efficiencies have been obtained by using Monte Carlo simulation and from the conventional calibration experiment. For the calibration experiment, a torso phantom containing a point source is used. The minimum detectable activity (MDA) for 137Cs for 10min counting interval is 448±47 Bq. The results indicate that the calibration of the whole body counter by the MCNPX code can be substituted for the actual calibration. It is shown that, the Monte Carlo simulation is an inexpensive alternative method to obtain the counting efficiency of the chair type WBC for design and accurate calibration purposes.}, keywords = {Whole-Body Counter,Calibration,Efficiency,Monte Carlo Simulation,BOMAB and Torso Phantom}, title_fa = {طراحی و کالیبراسیون یک سامانه‌ی شمارنده‌ی کل بدن با هندسه‌ی صندلی}, abstract_fa = {شمارنده­‌های کل بدن برای اندازه‌گیری‌های مستقیم پرتوزایی بدن و ارزیابی پرتوگیری داخلی برای پرتوکاران و دیگر افراد جامعه استفاده می‌شوند. شمارنده­‌ی با هندسه­‌ی صندلی نسبت به دیگر هندسه­‌ها برای پایش سریع در حوادث پرتوی، مناسب‌­تر است. در این پژوهش، سیستم پایش قابل حملی با هندسه­‌ی صندلی، طراحی شد و ارزیابی بازده­‌ی شمارش برای کالیبراسیون سیستم انجام گرفت. این سامانه از یک آشکارساز سوسوزن یدور سدیم (قطر cm5×cm5) قرار گرفته داخل یک موازی­‌ساز، و یک صندلی که با لایه­‌های سربی به ضخامت 2cm حفاظت شده‌­اند، تشکیل شده است. برای محاسبه­‌ی زاویه­‌ی صندلی و زاویه‌­ی موازی­‌ساز، از مدل فانتوم بومَب استفاده شده است. بازده شمارش‌­ها از راه شبیه‌­سازی مونته­‌کارلو و آزمایش‌­های کالیبراسیون معمول و با استفاده از یک فانتوم نیم‌­تنه‌­ی حاوی چشمه‌­ی نقطه­‌ای به دست آمد. کمینه‌ی سطح پرتوزایی قابل اندازه‌گیری (MDA) برای چشمه‌ی Cs137 در محدوده­‌ی زمانی min 10، برابر با Bq 47±448 بود. نتایج حاکی از آن است که کالیبراسیون شمارنده­‌ی کل بدن با کد MCNPX می­‌تواند جای­گزین کالیبراسیون واقعی شود. هم­‌چنین نشان داده شد که شبیه­‌سازی مونته­‌کارلو، یک روش ارزان‌­قیمت برای به دست آوردن بازده­‌ی شمارنده­‌ی کل بدن از نوع صندلی برای مقاصد طراحی و کالیبراسیون است.}, keywords_fa = {Whole-Body Counter,Calibration,Efficiency,Monte Carlo Simulation,BOMAB and Torso Phantom}, url = {https://jonsat.nstri.ir/article_133.html}, eprint = {https://jonsat.nstri.ir/article_133_72cfb110d1f97e8610257e1afc3038c2.pdf} } @article { author = {Betesho, R and Ghotbikohan, Kh and Nabardi, F and Rafiee, R}, title = {A Study on the Effect of Gamma Rays on Reducing the Burden of Some Pathogens in Sewage Sludge}, journal = {Journal of Nuclear Science and Technology (JONSAT)}, volume = {37}, number = {4}, pages = {24-33}, year = {2017}, publisher = {Nuclear Science and Technology Research Institute}, issn = {1735-1871}, eissn = {2676-5861}, doi = {}, abstract = {: The reuse of sludge in agriculture leads to the transfer of some pollutants into food chain, thus hazarding the public health. The pathogens, heavy metals and nutrients in the sewage sludge from two wastewater treatment plants in Tehran-Iran, Shahid Mahallati and Ekbatan, were investigated in three independent samplings. Moreover, the reduction of pathogens after irradiation by 10kGy gamma ray from 60Co was studied. The obtained results indicated that the heavy metals and nutrients in both of the wastewater treatment plants comply with Environmental Pollution Agency Standards and the pathogens counts reduced to the extent of the permitted level after irradiation. Viable Ascaris eggs in Ekbatan sludge was more than permitted level even after irradiation. According to the obtained data, just the sewage sludge of Shahid Mahallati treatment plant produced class A biosolids by irradiation which means that it can be applied to the agricultural lands, public contact sites and even home gardens. The odor of irradiated samples reduced as compared with the control ones. Vector attraction reduction processes must be conducted before use. The capability of the mentioned dose of gamma ray in converting the municipal sewage sludge into a sanitary fertilizer, depends on the microbial contamination level, specially the numbers of viable Ascaris eggs.}, keywords = {Wastewater,Sanitary Fertilizer,Irradiation,Ascaris,Pollutants}, title_fa = {مطالعه‌ی تأثیر پرتو گاما بر کاهش بار برخی عوامل بیماری‌زای موجود در لجن فاضلاب شهری}, abstract_fa = {استفاده از لجن فاضلاب در کشاورزی، باعث انتقال آلاینده­‌ها به زنجیره­‌ی غذایی و انتشار آنها می‌­شود. در این مقاله، میزان عوامل بیماری­‌زا و نیز فلزهای سنگین و مغذی در لجن حاصل از فاضلاب تصفیه‌­خانه­‌های شهری اکباتان و شهید محلاتی (تهران) در سه نوبت نمونه‌­برداری مستقل بررسی شد. هم­چنین کاهش عوامل بیماری­‌زا در لجن به دست آمده با دز kGy10پرتو گاما حاصل از Co60 مطالعه شد. نتایج نشان داد که لجن تصفیه‌­خانه­‌ها از نظر مقدار فلزهای سنگین و مغذی در محدوده­‌ی مجاز استاندارد است. بوی نمونه­‌های پرتودیده کم­تر از نمونه‌­های شاهد بود. میزان عوامل بیماری‌­زا پس از تابش‌­دهی به زیر حد مجاز رسید، در حالی­که تعداد تخم‌­های زنده­‌ی آسکاریس در لجن تصفیه‌­خانه اکباتان حتی پس از تاب‌ش­ده‌ی‏، بالاتر از حد مجاز بود. با توجه به این نتایج، فقط لجن تصفیه­‌خانه­‌ی شهید محلاتی به لجن کلاس A تبدیل شد، به این معنی که بتواند در باغ­‌ها و حتی منازل قابل استفاده باشد. ضروری است  قبل از استفاده از این لجن، الزامات کاهش تجمع حشرات به کار گرفته شود. قابلیت به کارگیری دز مزبور به منظور تبدیل لجن به کود بهداشتی، به دلیل ثابت نبودن آلودگی میکروبی، منوط به تعیین آلودگی اولیه است.}, keywords_fa = {Wastewater,Sanitary Fertilizer,Irradiation,Ascaris,Pollutants}, url = {https://jonsat.nstri.ir/article_134.html}, eprint = {https://jonsat.nstri.ir/article_134_3215c555151ff4991bd32f0ba7c7ae19.pdf} } @article { author = {Esteki, M. H and Khorsandi, J and Esteki, M. H and Kaviani, P}, title = {Measurement of the Cadmium Ratio in Esfahan Heavy Water Zero Power Reactor and Comparison of the Values Obtained in Two Different Pitches}, journal = {Journal of Nuclear Science and Technology (JONSAT)}, volume = {37}, number = {4}, pages = {34-41}, year = {2017}, publisher = {Nuclear Science and Technology Research Institute}, issn = {1735-1871}, eissn = {2676-5861}, doi = {}, abstract = { Measurement of cadmium ratio is one of the basic parameters in nuclear reactors. In this paper, the amount of cadmium ratio for the Esfahan Heavy Water Zero Power Reactor (EHWZPR) in two pitches of 18 and 20cm have been measured. For the cadmium ratio measurements Mn-Ni foils were used. The activity of the Mn-Ni foils were obtained by plastic scintillator and NaI(Tl) detectors for beta and gamma rays. Also, changes of the cadmium ratio in the axial direction of the reactor, asymptotic region or stable spectrum were obtained. The length of stable spectrum of the reactor increased to approximately 19cm, in pitch of 20 to 18, due to the reduced number of fuel rods and critical height of heavy water. To verify the measured values, the Esfahan Heavy Water Zero Power Reactor was simulated with the MCNPX-2.6.0 code. The  results of simulation were in good agreement with those of the experiments.  }, keywords = {Zero Power Reactor,Cadmium Ratio,Manganese Foil,Asymptotic Region,Heavy Water,Neutron Activation}, title_fa = {اندازه‌گیری نسبت کادمیم در راکتور صفر- قدرت آب سنگین اصفهان و مقایسه‌ی مقادیر به دست آمده در دو گام مختلف}, abstract_fa = {اندازه­‌گیری نسبت کادمیم یکی از پارامترهای اساسی در راکتورهای هسته‌­ای است. در این مقاله، مقدار نسبت کادمیم برای راکتور صفر- قدرت آب سنگین اصفهان (HWZPR) در دو گام 18 وcm 20 اندازه­‌گیری شده است. از پولک­های منگنز- نیکل برای اندازه­‌گیری نسبت کادمیم استفاده شده است. پرتوزایی پولک‌­ها با آشکارساز سوسوزن پلاستیکی و یدور سدیم برای پرتوهای بتا و گاما به ­دست آمده است. هم­‌چنین از تغییرات مقدار نسبت کادمیم در راستای محوری راکتور، ناحیه­‌ی مجانبی یا طیف پایدار به­ دست آمده است. طیف ثابت راکتور، در گام 20، تقریباً cm19 نسبت به گام 18 افزایش یافته است، که این به دلیل کاهش تعداد میله­‌های سوخت و افزایش ارتفاع بحرانی آب سنگین است. برای بررسی درستی مقادیر تجربی اندازه­‌گیری شده، راکتور صفر- قدرت آب سنگین اصفهان با کد MCNPX-2.6.0 شبیه‌­سازی شد. نتایج حاصل از شبیه­‌سازی و تجربی سازگاری خوبی با هم داشتند.}, keywords_fa = {Zero Power Reactor,Cadmium Ratio,Manganese Foil,Asymptotic Region,Heavy Water,Neutron Activation}, url = {https://jonsat.nstri.ir/article_135.html}, eprint = {https://jonsat.nstri.ir/article_135_570549b13e3ad739c94942ccddd60c8f.pdf} } @article { author = {Yousefpour, F and Zarnooshe Farahani, A and RahGoshay, M and Hoseyni, S. M}, title = {Development of a Qualified MELCOR Model for IR-360 NPP Using SNAP Software}, journal = {Journal of Nuclear Science and Technology (JONSAT)}, volume = {37}, number = {4}, pages = {42-55}, year = {2017}, publisher = {Nuclear Science and Technology Research Institute}, issn = {1735-1871}, eissn = {2676-5861}, doi = {}, abstract = {Development of a qualified thermal-hydraulics and the severe accident model of nuclear power plants (NPPs) is of crucial importance in their design, optimization and safety evaluation. This is also the first step in the safety analysis of the IR-360 NPP for which its design is domestically in process. Without an approved and “qualified" model, deterministic safety analysis (DSA) results are not reliable. In fact, the quality of the developed model should be assessed to ensure the reliability of the analysis results. This study attempts to develop a qualified MELCOR model for the IR-360 nuclear power plant in the SNAP nuclear analysis software. By selecting the appropriate nodalization of the problem and their proper connections, the most important thermo-hydraulics parameters such as pressure and temperature of the fluid, mass flow rate, direction and magnitude of the flow in the primary loop, etc are calculated. A comparison is made between the design parameters and calculated values to obtain the deviation of the model values from the design data. The calculated deviations shown to be below the acceptable limits, specified by the DSA practice including the suggestions of the International Atomic Energy Agency (IAEA). This confirms the qualification of the developed model for the safety analysis of the plant in the next steps.}, keywords = {Pressurized Nuclear Power Plant,Primary Loop,Modeling,MELCOR Code,SNAP Software,Nodalization}, title_fa = {توسعه‌ی مدل معتبر MELCOR نیروگاه هسته‌ای IR-360 با استفاده از نرم‌افزار SNAP}, abstract_fa = {توسعه‌­ی مدل ترموهیدرولیکی و معتبر حادثه­‌ی شدید برای تحلیل رفتار پویای نیروگاه‌های هسته‌ای در طراحی، بهینه‌سازی و ارزیابی ایمنی این نیروگاه‌ها حائز اهمیت است. برای نیروگاه بومی در حال طراحی IR-360 نیز توسعه­‌ی چنین مدلی، اولین گام در تحلیل ایمنی است. آنالیزهای ایمنی قطعی (DSA) بدون اعتبارسنجی مدل مورد نظر، قابل اعتماد نیست. در واقع لازم است صحت مدل توسعه‌ یافته ارزیابی شود تا اطمینان لازم در خصوص اعتمادپذیر بودن آنالیز‌های صورت گرفته تضمین‌ شود. این پژوهش تلاش دارد تا مدل MELCOR معتبر برای نیروگاه IR-360 را توسعه دهد. به این منظور و برای کمینه کردن خطای کاربر، از نرم‌افزار آنالیز هسته‌ای SNAP استفاده شده است. با انتخاب گره‌­بندی مناسب مسئله در ساختار این کد، پارامترهای کلیدی از جمله فشار و دمای سیال، دبی جرمی و مانند آن، در هر حجم‌کنترل و مسیر ‌جریان در نیروگاه هسته‌ای بررسی شده است. هم­چنین در این­­جا با مقایسه‌­ی بین پارامتر‌های طراحی و مقادیر محاسبه شده، میزان خطای ناشی از مدل­سازی به دست آمده است. انحراف و خطای محاسباتی کم­تر از حدود تعیین شده در ضوابط و معیار‌های قابل پذیرش آژانس بین‌المللی انرژی اتمی است، که نشان‌­دهنده­‌ی اعتبار و کیفیت مدل موردنظر به منظور انجام تجزیه و تحلیل‌های بعدی است.  }, keywords_fa = {Pressurized Nuclear Power Plant,Primary Loop,Modeling,MELCOR Code,SNAP Software,Nodalization}, url = {https://jonsat.nstri.ir/article_136.html}, eprint = {https://jonsat.nstri.ir/article_136_142d591add0c16288fa58ae337148e8b.pdf} } @article { author = {Mirzaii, M and Abdi, Z and Yousefi, K and Rahimi, M and kAKAVAND, T and Fazli, SH}, title = {Investigation of 18F and 13N Radioisotopes Production Using Cyclotron Recirculating Liquid Target}, journal = {Journal of Nuclear Science and Technology (JONSAT)}, volume = {37}, number = {4}, pages = {56-62}, year = {2017}, publisher = {Nuclear Science and Technology Research Institute}, issn = {1735-1871}, eissn = {2676-5861}, doi = {}, abstract = {Two radioisotopes of 18F (T1/2=109.7 min, Iβ+= 97%, Eβ+= 0.63 MeV), and 13N (T1/2=10min, Iβ+=100%, Eβ+=0.96 MeV) decay almost completely via positron emission. Due to this characteristic, these radioisotopes are used in PET (positron emission tomography) camera for detection of cancer cells. In this article, after calculating the excitation function for nuclear reactions leading to the 18F, 18O (p, n) 18F, and 13N, 16O (p, α) 13N formation using the ALICE-91 nuclear code and by a comparison of the results with the experimental data, the best range of energy to produce with a cyclotron accelerator and the amount of heat deposited to the target material, was determined. For the waste heat removal, a miniature heat exchanger was designed and manufactured. A thermal design of the heat exchanger by the Aspen HTFS+ software was created, and its mechanical plan sheet was drawn using the SolidWorks software. After the fabrication of the heat exchanger and recirculation liquid target located at the liquid target room, 13N was produced via pure water proton bombardment with 17.5 MeV energies verifying the theoretical calculations.  }, keywords = {18F,13N,Positron Emitter,Cyclotron,Recirculation Liquid Target,Miniature Heat Exchanger}, title_fa = {بررسی تولید رادیوایزوتوپ‌های 18F و 13N با استفاده از هدف مایع چرخشی سیکلوترون}, abstract_fa = { (با عرض پوزش چکیده مقاله به دلیل وجود مشکلات سایت با اشکال فراوان همراه است لطفا از روی پی دی اف مطالعه فرمایید) دو رادیوایزوتوپ  18F (T1/2=109.7 min, Iβ+= 97%, Eβ+= 0.63 MeV) و 13N (T1/2=10min, Iβ+=100%, Eβ+=0.96 MeV)، min    کامل تقریباً از طریق گسیل پوزیترون واپاشی می­‌کنند. به همین سبب، از این دو رادیوایزوتوپ به منظور مقطع­‌نگاری گسیل پوزیترون (پی ای تی) در تشخیص سلول‌های سرطانی استفاده   می‌شود. در این مقاله، پس از محاسبه­‌ی توابع برانگیختگی برای واکنش‌­های هسته­‌ای منجر به 18F, 18O (p, n) 18F, و 13N, 16O (p, α) 13N برای تولید با شتاب‌­دهنده­‌ی سیکلوترون و میزان حرارت سپرده شده به مایع هدف تعیین شد. برای برداشت حرارت ایجاد شده‌­ی حاصل از پرتوی فرودی در هدف، یک مبدل حرارتی مینیاتوری طراحی و ساخته شد. طراحی حرارتی این مبدل با استفاده از نرم‌­افزار Aspen HTFS+ انجام شد. نقشه­ی ساخت آن نیز با نرم­‌افزار SolidWorks ترسیم شد. پس از ساخت مبدل حرارتی و جانمایی هدف مایع چرخشی در اتاق هدف مایع، تولید N13 از راه بمباران پروتونی آب خالص با انرژی MeV17.5 به منظور صحه­‌گذاری محاسبات نظری انجام گرف.}, keywords_fa = {18F,13N,Positron Emitter,Cyclotron,Recirculation Liquid Target,Miniature Heat Exchanger}, url = {https://jonsat.nstri.ir/article_137.html}, eprint = {https://jonsat.nstri.ir/article_137_6fce486018f211bd4008a01e02cdbf0a.pdf} } @article { author = {Moghaddam B, L and Bahrami-Samani, A and Fathi, F and Shamsaee, M}, title = {Production, Radiolabeling and Biodistribution of 47/46Sc-DOTMP as a Radiopharmaceutical}, journal = {Journal of Nuclear Science and Technology (JONSAT)}, volume = {37}, number = {4}, pages = {63-69}, year = {2017}, publisher = {Nuclear Science and Technology Research Institute}, issn = {1735-1871}, eissn = {2676-5861}, doi = {}, abstract = {Designing ideal radiopharmaceuticals for use as the bone pain palliatives requires the utilization of a moderate or low energy β-emitters with a stable carrier molecule. In this direction, cyclic polyaminophosphonic acids are known to form thermodynamically more stable and kinetically more inert complexes with lanthanides, compared to their acyclic analogs. In this study, DOTMP as the cyclic polyaminophosphonic acid and bone-seeking ligand, and 47Sc radioisotope as a low energy β-emitter with the maximum energies of 0.600MeV and 0.441MeV and the short half-life of 3.47d were considered and the therapeutic potential of the bone seeking radiopharmaceutical 47Sc-DOTMP was assessed by measuring its skeletal uptake in the animal model. Because of the limited availability of 47Sc, this study was performed  upon using 46Sc radioisotope which is chemically identical. 46Sc was produced with an activity of 2.3 (85.1 MBq) mCi by irradiation of natural 45Sc2O3 target at a thermal neutron flux of 3.5×1013 n/cm2.s in 48h at the Tehran Research Reactor (TRR). 46Sc-DOTMP was prepared in radiochemical purity of about 90% in a chelant-to-metal ratio of 60:1. The in-vitro stability of the complex was evaluated at room temperature for 48h. Then, the biodistribution studies of the complex in 5 groups of mice were carried out for 7d.}, keywords = {Bone-Seeking Radiopharmaceutical,46Sc-DOTMP,Radiolabeling,Biodistribution}, title_fa = {تولید، نشان‌دارسازی و بررسی توزیع بیولوژیکی رادیوداروی 47.46Sc-DOTMP}, abstract_fa = {برای طراحی رادیوداروهای مناسب به منظور استفاده در تسکین دردهای استخوانی، به رادیوایزوتوپ­‌های گسیل­‌کننده­‌ی –β با انرژی متوسط یا کم و یک مولکول حمل­‌کننده و پایدار نیاز است. در این راستا، لیگاندهای پلی­‌آمینوفسفونیک اسید­های حلقوی به صورت موادی که ترکیباتی با پایداری ترمودینامیکی و مقاومت جنبشی بالاتری با فلزها نسبت به مشابه مارپیچی خود تشکیل می‌­دهند، شناخته می‌­شوند. در این پروژه، استفاده از 1،4،7،10- تتراآزاسیکلودودکان-1،4،7،10- تترامتیلن فسفونیک اسید (DOTMP) به شکل یک لیگاند پلی­‌آمینوفسفونیک اسید حلقوی و استخوان­‌خواه، و رادیوایزوتوپ 47Sc در نقش یک گسیلنده­‌ی کم­­‌انرژی –β با انرژی­‌های بیشینه MeV0.006 و MeV0.441 و نیمه­‌عمری برابر با d3.4 در نظر گرفته شد. پتانسیل درمانی این رادیوداروی استخوان­‌خواه از راه نشان‌­دارسازی 1،4،7،10- تتراآزاسیکلودودکان-1،4،7،10- تترامتیلن فسفونیک اسید (DOTMP) با 47Sc و اندازه‏‌گیری مقدار جذب اسکلتی آن در مدل حیوانی ارزیابی شد. به دلیل محدودیت دسترسی به رادیوایزوتوپ 46Sc، این پروژه با استفاده از رادیوایزوتوپ 46Sc که دارای خواص شیمیایی مشابه است، انجام شد. 46Sc با پرتوزایی در حدود MBq 85.1 (mCi2.3) و بمباران اکسید Sc طبیعی به مدت زمان h48 تحت شار نوترونی . 1013*3.5 n/cm2.s در راکتور تحقیقاتی تهران، تولید شد. رادیوداروی 46Sc-DOTMP با خلوص رادیوشیمیایی بالاتر از 95% و نسبت لیگاند به فلز 1:60 تهیه، و پایداری آزمایشگاهی آن به مدت h48 و در دمای اتاق ارزیابی، و سپس توزیع بیولوژیکی آن در موش­‌ها تا 7 روز بررسی شد.}, keywords_fa = {Bone-Seeking Radiopharmaceutical,46Sc-DOTMP,Radiolabeling,Biodistribution}, url = {https://jonsat.nstri.ir/article_138.html}, eprint = {https://jonsat.nstri.ir/article_138_1f731b78e1b516dc7c43882c6b993a1b.pdf} } @article { author = {A. Milani, S}, title = {Solid Phase Extraction of Thorium (IV) and Uranium (VI) from Nitrate Medium Using Cyanex 302-Coated Magnetic Nanoparticles}, journal = {Journal of Nuclear Science and Technology (JONSAT)}, volume = {37}, number = {4}, pages = {70-76}, year = {2017}, publisher = {Nuclear Science and Technology Research Institute}, issn = {1735-1871}, eissn = {2676-5861}, doi = {}, abstract = {Magnetic nanoparticles modifdied with Cyanex 302 were used for the separation and preconcentration of Th(IV) and U(VI) from synthetic nitrate solutions. The capacity of magnetic nanoparticles (≈10 nm) coated with Cyanex 302 for simultaneous separation and preconcentration of thorium and uranium from the nitratemedium was studied by means of the batch method. The effects of analytical parameters, including the amount of Cyanex 302, pH, and initial metal concentration on the extractive behavior of metal ions were systematically studied. The results showed that the optimum weight ratio of Cyanex 302 to magnetite nanoparticles was 10% and the optimum pH of solution for the simultaneous extraction of Th(IV) and U(VI) was equal to 6. The maximal capacity of the magnetite nanoparticles modifdied with 10w% Cyanex 302 was found to be 60 mg l-1 of thorium and uranium. The influences of the fission products [Cs(I), Sr(II)] and interfering ions, including Fe(III), Cr(III), Mg(II), Mn(II) and Al(III) were also investigated}, keywords = {Solid Phase Extraction,Thorium and Uranium,Cyanex 302,Magnetic Nanoparticles}, title_fa = {استخراج فاز جامد توریم (IV) و اورانیم (VI) از محیط نیتراتی با نانوذرات مغناطیسی اصلاح شده با سیانکس 302}, abstract_fa = {با استفاده از نانوذرات مغناطیسی اصلاح شده با سیانکس 302، یک جاذب مغناطیسی برای استخراج یون­های توریم و اورانیم از محیط­‌های نیتراتی ساختگی فراهم شد. توانایی و قابلیت نانوذرات مغناطیسی (10nm≈) پوشش داده شده با سیانکس 302 برای استخراج و پیش‌­تغلیظ هم­‌زمان توریم و اورانیم از محیط نیتراتی در روش ناپیوسته ارزیابی شد. اثر مقدار لیگاند، pH محیط، و غلظت اولیه­‌ی محلول یون­های فلزی بر رفتار استخراجی یون­‌های توریم و اورانیم بررسی شد. داده­‌های آزمایشگاهی حاکی از آن است که نسبت وزنی بهینه‌­ی سیانکس 302 به نانوذرات مغناطیسی، 10% وزنی، و مقدار pH بهینه­‌ی محلول برای استخراج هم‌­زمان یون­‌های توریم و اورانیم برابر با 6 است. این مقدار سیانکس قابلیت جذب  60 mg/Iیون توریم و اورانیم را دارد. تأثیر حضور محصولات شکافت [(I)Sr(II),Cs] و یون­‌های مزاحم از جمله (III)Mn(II),Mg(II),Cr (III),Fe و (III)Al نیز بررسی شد.}, keywords_fa = {Solid Phase Extraction,Thorium and Uranium,Cyanex 302,Magnetic Nanoparticles}, url = {https://jonsat.nstri.ir/article_139.html}, eprint = {https://jonsat.nstri.ir/article_139_1d7456158e3f5f918083ce26dd8c1584.pdf} } @article { author = {Entezam, M and Daneshian, H and Parsaian, M. R and Ahmadian, V}, title = {Study of High Energy Electron Beam Irradiation Dose Effects on Physical and Thermal Properties of PVA-Based Hydrogels}, journal = {Journal of Nuclear Science and Technology (JONSAT)}, volume = {37}, number = {4}, pages = {77-85}, year = {2017}, publisher = {Nuclear Science and Technology Research Institute}, issn = {1735-1871}, eissn = {2676-5861}, doi = {}, abstract = {Polyvinyl alcohol (PVA) with the desired bio-properties and relatively low cost has attracted special interest to make hydrogels, especially with the wound dressing application. On the one hand, irradiation is an appropriate method to prepare hydrogels based on PVA. In this method, the irradiation conditions, especially the irradiation dose, influence significantly the physical properties and therefore affect the performance of the hydrogel. The main objective of this research was to investigate the effect of electron beam irradiation dose on the physical and thermal (crystallinity) properties of PVA hydrogels. The hydrogels were prepared by irradiation of the aqueous solution of PVA (7 wt.%) at different doses. The gel content, equilibrium swelling degree and dehydration behavior of the hydrogels were evaluated. The chemical structure changes of the PVA due to irradiation and thermal behavior of the dried PVA gels were probed respectively by FTIR and DCS experiments. In the wake of increasing the dose, the gel content of the hydrogel increased marginally, while its swelling decreased significantly. There was no obvious effect on the hydrogel dehydration by changing in the dose. The FTIR results showed that besides the crosslinking, the PVA chains degradation was also augmented with the dose. According to the DSC results, increasing the dose caused reduction of the crystallization and melt temperatures of the PVA and increment of its crystallinity.}, keywords = {High Energy Electron Beam Irradiation,Polyvinyl Alcohol,Hydrogel,Physical Properties,Crystallinity}, title_fa = {مطالعه‌ی آثار دز تابش‌دهی باریکه‌ی الکترونی انرژی بالا بر خواص فیزیکی و حرارتی هیدروژل‌ها بر پایه‌ی پلی وینیل الکل‌}, abstract_fa = {پلی­وینیل الکل (PVA) با خواص زیستی مناسب و قیمت نسبتاً ارزان، توجه ویژه­ای را در ساخت هیدروژل­‌ها، به ویژه با کاربرد پانسمان زخم، به خود اختصاص داده است. از طرفی تاب‌ش­دهی، روشی مطلوب برای تهیه‌­ی هیدروژل­‌ها بر پایه­‌ی PVA به شمار می‌­آید. در این روش، شرایط تابش­‌دهی، به ویژه دز تابش‌­دهی، بر خواص فیزیکی و در نتیجه کارایی هیدروژل بسیار مؤثر است. هدف از انجام این پژوهش، بررسی اثر دز تابش­‌دهی الکترونی بر خواص فیزیکی و حرارتی (بلورینگی) هیدروژل‌­های PVA بود. هیدروژل­‌ها با تابش‌­دهی محلول آبی PVA (wt 7%)، تحت دزهای مختلف تهیه شدند. میزان ژل، درجه­‌ی تورم تعادلی و رفتار دهیدراسیون هیدروژل­‌ها ارزیابی شدند. تغییرات شیمیایی ساختار PVA ناشی از تابش­‌دهی با آزمون FTIR، و رفتار حرارتی ژل­‌های خشک PVA  با آزمون DSC بررسی شدند. با افزایش دز تابش‌­دهی، میزان ژل هیدروژل افزایش اندکی نشان داد، در حالی که میزان تورم آن با کاهش چشم‌گیری همراه بود. دز تابش‌­دهی اثر قابل­‌توجه‌ی بر دهیدراسیون هیدروژل نداشت. نتایج آزمون FTIR نشان دادند که علاوه بر شبکه­‌ای شدن، تخریب زنجیره­‌های PVA نیز با افزایش دز تابش‌­دهی شدت می­‌گیرد. براساس نتایج آزمون DSC، افزایش دز تابش‌­دهی موجب کاهش دماهای بلورینگی و ذوب PVA، و البته افزایش میزان بلورینگی آن شد.}, keywords_fa = {High Energy Electron Beam Irradiation,Polyvinyl Alcohol,Hydrogel,Physical Properties,Crystallinity}, url = {https://jonsat.nstri.ir/article_140.html}, eprint = {https://jonsat.nstri.ir/article_140_116f50c10a7dd12a7f1c323a3ff13c47.pdf} }