@article { author = {Khorasani, A and Mousavi Shalmani, M.A and Piervali Bieranvand, N}, title = {Comparison of Time Domain Reflectometry, Capacitance Methods and Neutron Scattering in Soil Moisture Measurements}, journal = {Journal of Nuclear Science and Technology (JONSAT)}, volume = {32}, number = {3}, pages = {1-7}, year = {2011}, publisher = {Nuclear Science and Technology Research Institute}, issn = {1735-1871}, eissn = {2676-5861}, doi = {}, abstract = {An accurate, precise, fast and ease as well as the ability for measurements in depth are the characteristics that are desirable in measuring soil moisture methods. To compare methods (time domain reflectometry and capacitance) with neutron scattering for soil water monitoring, an experiment was carried out in a randomized complete block (RCB) design (Split Split plot) on tomato with three replications on the experimental field of IAEA (Seibersdorf-Austria). The treatment instruments for the soil moisture monitoring (main factor) consist of neutron gauge, Diviner2000, time domain reflectometer (TDR) and an EnviroScan and different irrigation systems (first sub factor) consist of trickle and furrow irrigations and different depths of soil (second sub factor) consist of 0-20, 20-40 and 40-60cm. The results showed that for the neutron gauge and TDR the amount of soil moisture in both of trickle and furrow irrigations were the same, but the significant differences were recorded in Diviner2000 and EnviroScan measurements. The results of this study showed that the neutron gauge is an acceptable and reliable means with the modern technology, with a precision of ±2mm in 450mm soil water to a depth of 1.5 meter and can be considered as the most practical method for measuring soil moisture profiles and irrigation planning program. The TDR method in most mineral soils, without the need for calibration, with an accuracy ±0.01m3m-3 has a good performance in soil moisture and electrical conductivity measurements. The Diviner2000 and EnviroScan are not well suitable for the above conditions for several reasons such as much higher soil moisture and a large error measurement and also its sensitivity to the soil gap and to the small change in the soil moisture in comparison with the neutron gauge and the TDR methods.}, keywords = {Irrigation,Soil Moisture,Neutron Gauge,TDR,Diviner2000,EnviroScan}, title_fa = {مقایسه‌ی روش‌های انعکاس‌سنجی زمانی و ظرفیت‌سنجی با روش پراکندگی نوترون در اندازه‌گیری رطوبت خاک}, abstract_fa = {از مشخصات مطلوب روش‌های اندازه‌گیری رطوبت خاک، دقت، صحت، سرعت، سهولت و توانایی سنجش در عمق آن‌ می‌باشد. به منظور مقایسه­ی روش‌های انعکاس‌سنجی زمانی و ظرفیت‌سنجی با روش پراکندگی نوترون در اندازه‌گیری رطوبت خاک، آزمایش مزرعه‌ای در قالب طرح بلوک کامل تصادفی، به صورت کرت دو بار خرد شده، در سه تکرار (مجموعاً دوازده کرت)، در مزرعه­ی تحقیقاتی مرکز آزمایشگاه‌های آژانس بین‌ا‌لمللی انرژی اتمی در سایبرزدورف اتریش بر روی گیاه گوجه فرنگی به اجرا درآمد. دستگاه­های اندازه‌گیری رطوبت خاک شامل نوترون‌سنج، انعکاس‌سنج ‌زمانی و ظرفیت­سنج­های Diviner2000 و EnviroScan به عنوان عامل اصلی، سیستم‌های مختلف آبیاری شامل آبیاری شیاری و قطره‌ای (عامل فرعی اول) و اعماق مختلف خاک شامل ◦ تا 20، 20 تا 40 و 40 تا 60 سانتی‌متر (عامل فرعی دوم) بودند. نتایج نشان داد که رطوبت اندازه‌گیری شده با نوترون‌سنج و انعکاس­سنج زمانی در دو تیمار آبیاری شیاری و قطره‌ای یکسان است. این در حالی است که اختلاف معنی‌داری در میزان رطوبت اندازه‌گیری شده با دستگاه‌های Diviner2000 و EnviroScan ملاحظه شد. نتایج حاصل از این تحقیق نشان داد که نوترون‌سنج یک وسیله­ی قابل قبول و مورد اعتماد با فن­آوری جدید، و دقت 2± میلی­متر در 450 میلی­متر آب خاک تا عمق 1.5 متری و روش پراکندگی نوترون، کاربردی­ترین روش برای اندازه­گیری پروفیل رطوبتی خاک و برنامه­ریزی آبیاری می­باشد. انعکاس­سنج زمانی در اغلب خاک­های معدنی بدون نیاز به کالیبراسیون با دقت ±0.01m3m-3 عملکرد خوبی داشته و هم زمان رطوبت و هدایت الکتریکی خاک را اندازه‌گیری می­کند. در شرایط بالا، دستگاه‌های Diviner2000 و EnviroScan چندان مناسب نبود‌ند که این امر می‌تواند به دلایلی مانند مقادیر اندازه‌گیری بیش­تر رطوبت خاک، خطای بالای اندازه‌گیری این دو دستگاه و هم­چنین حساسیت آن­ها به درز و شکاف خاک و تغییرات کم رطوبت خاک در مقایسه با دو دستگاه نوترون‌سنج و انعکاس­سنج زمانی باشد.}, keywords_fa = {Irrigation,Soil Moisture,Neutron Gauge,TDR,Diviner2000,EnviroScan}, url = {https://jonsat.nstri.ir/article_406.html}, eprint = {https://jonsat.nstri.ir/article_406_9fe8ae09a54100fde8d7463c23c25361.pdf} } @article { author = {Jamali Esfahlan, D and Madani, H}, title = {Comparison of Estimation and Simulation Methods for Modeling Block 1 of Anomaly No.3 in Narigan Uranium Mineral Deposit}, journal = {Journal of Nuclear Science and Technology (JONSAT)}, volume = {32}, number = {3}, pages = {8-18}, year = {2011}, publisher = {Nuclear Science and Technology Research Institute}, issn = {1735-1871}, eissn = {2676-5861}, doi = {}, abstract = {Geostatistical methods are applied for modeling the mineral deposits at the final stage of the detailed exploration. By applying the results of these models, the technical and economic feasibility studies are conducted for the deposits. The geostatistical modeling methods are usually consist of estimation and simulation methods. The estimation techniques, such as Kriging, construct spatial relation (geological continuation model) between data, by providing the best unique guesses for unknown features. However, when applying this technique for a grid of drill-holes over a deposit, an obvious discrepancy exists between the real geological features and the Kriging estimation map. Because of the limited number of sampled data applied for Kriging, it could not appear as the same as the real features. Also the spatial continuity estimated by the Kriging maps, are smoother than the real unknown features. On the other hand, the objective of simulation is to provide some functions or sets of variable values, to be compatible with the existing information. This means that the simulated values have an average and the variance similar to the raw data and may even be the same as the measurements. we studied the Anomaly No.3 of Narigan uranium mineral deposit, located in the central Iran region and applied the Kriging estimation and the sequential Gaussian simulation methods, and finally by comparing the results we concluded that the Kriging estimation method is more reliable for long term planning of a mine. Because of the reconstructing random structures, the results of the simulation methods indicate that they could also be applied for short term planning in mine exploitation.}, keywords = {Estimation,Simulation,Geostatistics,Uranium Deposit,Kriging}, title_fa = {مقایسه‌ی نتایج روش‌های تخمین و شبیه‌سازی زمین آماری برای مدل‌سازی کانسار کانی اورانیم در بلوک 1 آنومالی 3 ناریگان}, abstract_fa = {در پایان فاز تفصیلی اکتشاف برای مدل‌سازی کانسارهای معدنی به طور معمول از روش‌های زمین‌آماری استفاده می‌شود. با استفاده از نتایج حاصل از این مدل‌ها، مطالعات فنی و اقتصادی بر روی کانسار صورت می‌گیرد. روش‌های مدل‌سازی زمین‌آماری غالباً شامل روش‌های تخمین و شبیه‌سازی است. روش تخمین مانند کریگینگ، با استفاده از ارتباط فضایی (مدل پیوستگی زمین‌شناسی) بین داده‌ها بهترین حدس منحصر به فرد از ناشناخته‌ها را ایجاد می‌کند. با وجود این، در موقع کاربرد این روش برای یک شبکه­ی حفاری بر روی کانسار، متوجه یک تفاوت آشکار بین پدیده­ی زمین‌شناسی واقعی و نقشه­ی کریگینگ تخمین­ها می‌شویم. پیوستگی فضایی که به وسیله­ی نقشه­ی کریگینگ تخمین زده شده نمایش داده می‌شود، نرم‌تر از حقیقت ناشناخته است. در مقابل، هدف شبیه­سازی ایجاد تابع­ها یا مجموعه­ای از مقادیر متغیرها است که با اطلاعات موجود سازگار باشند. این اغلب بدین معنی است که مقادیر شبیه‌سازی شده دارای میانگین و واریانس مشابه با اطلاعات خام هستند و ممکن است که با داده‌های خام در نقاط اندازه­گیری شده برابر باشند. منطقه­ی مورد مطالعه کانسار اورانیم محدوده­ی 3 ناریگان واقع در ایران مرکزی است. برای این کانسار، روش‌های تخمین کریگینگ و شبیه‌سازی گاوسی متوالی انجام گردید، و در پایان با مقایسه­ی نتایج مشخص شد که نتایج روش‌ تخمین کریگینگ، به علت داشتن تخمین‌های محلی مناسب و ارایه­ی میانگین قابل‌قبول می‌تواند در برنامه‌ریزی‌های بلندمدت معدن­کاری استفاده شود. در مقابل، نتایج شبیه‌سازی به دلیل دوباره‌سازی ساختارهای تصادفی، می‌تواند در برنامه‌ریزی‌های کوتاه‌مدت مربوط به طراحی استخراج معدن مناسب باشد.}, keywords_fa = {Estimation,Simulation,Geostatistics,Uranium Deposit,Kriging}, url = {https://jonsat.nstri.ir/article_407.html}, eprint = {https://jonsat.nstri.ir/article_407_7e882022f9bd17ceb9613a0c4fa765e8.pdf} } @article { author = {Beigi, M and Hashemi, B and Allahverdi, M and Mahdavi, S.R and Ghiasi, H}, title = {Designing and Evaluating a Simple Small Phantom for Dosimetry Intercomparison of Iinacs Photon Beams}, journal = {Journal of Nuclear Science and Technology (JONSAT)}, volume = {32}, number = {3}, pages = {19-28}, year = {2011}, publisher = {Nuclear Science and Technology Research Institute}, issn = {1735-1871}, eissn = {2676-5861}, doi = {}, abstract = {This paper evaluate the functionality of a designed small phantom for determining the accuracy and performance of megavoltage radiotherapy machines through an external quality audit. The small phantom was designed to check the photon beams at the reference and some non-reference conditions on a linac at two radiotherapy centers in Tehran. LiF TLDs were used for experimental dosimetry. A standard phantom with an ionization chamber and the Monte Carlo code were used to calculate the conversion factor of the doses in the small phantom to the conventional condition. The result of this study showed that the dose conversion factors derived from the measurements made in the designed and standard phantoms are in good agreement with those calculated from the MCNPX simulations. At the reference condition, the amount of difference between the simulation and measurement were 0.5 at 6 and 18 MV. The differences for the 7cm×7cm field were 0.2% and 0.3% respectively, while for the 20cm×20cm field were 0.1% and 0.6%, respectively for the above energy. Using the designed phantom, two similar Varian linacs were checked at the reference conditions and amounts of their deviation between the planned and measured doses were estimated. The amount of variations of the phantom dose conversion factor with the field size indicates that the small designed phantom is not only appropriate for the small field sizes but also for the large ones. The results confirmed the functionality of the designed simple phantom with TLDs as an appropriate mailing system to carry out dosimetric intercomparison among different radiotherapy centers.}, keywords = {Quality Audit,Radiotherapy,Phantom,Ionization Chamber,Thermoluminescent Dosimetry,Quality Control,Photon Beams,Monte Carlo Method}, title_fa = {طراحی و ارزیابی یک فانتوم کوچک ساده به منظور مقایسه‌ی متقابل دزیمتری باریکه‌های فوتونی شتاب‌دهنده‌های خطی (لیناک) در بین مراکز پرتودرمانی}, abstract_fa = {این مقاله، امکان به کارگیری یک فانتوم کوچک برای تعیین صحت و عملکرد ماشین­های پرتودرمانی مگاولتی از طریق یک بازبینی کیفی مقایسه­ای را بررسی می­کند. فانتوم کوچکی برای بررسی باریکه­های فوتونی شتاب­دهنده­های خطی تحت شرایط مرجع و غیرمرجع در دو مرکز رادیوتراپی در تهران طراحی و از دزیمترهای ترمولومینسانس برای انجام دزسنجی تجربی استفاده شد. برای محاسبه­ی ضریب تبدیل دز در فانتوم کوچک (cm10×cm10×cm10) به شرایط معمول بخش­های پرتودرمانی از یک اتاقک یونش و کد مونت­کارلو استفاده شد. نتایج این مطالعه نشان داد که ضریب تبدیل به دست آمده از اندازه­گیری در عمق یکسان در دو فانتوم کوچک و استاندارد با مقادیر به دست آمده از شبیه­سازی به خوبی مطابقت می­کند. در شرایط مرجع، میزان اختلاف بین اندازه­گیری تجربی و شبیه­سازی برای هر دو انرژی 6 و MV18 برابر 0.5  درصد بود. این اختلاف برای انرژی­های 6 و MV18 در میدان­های با ابعاد cm7×cm7 به ترتیب برابر با 0.2%  و 0.3%  و در میدان با ابعاد cm20×cm20 به ترتیب، برابر با 0.1%  و 0.6% به دست آمد. با استفاده از فانتوم طراحی شده دو شتاب­دهنده­ی واریان تحت شرایط مرجع و غیرمرجع بررسی شدند و میزان انحراف بین دز اندازه­گیری شده و محاسبه شده به دست آمد. تغییرات ضریب تبدیل دز با ابعاد میدان حاکی از این است که این فانتوم نه تنها برای میدان­های با ابعاد کوچک بلکه برای میدان­های با ابعاد بزرگ نیز مناسب است. نتایج این مطالعه تأییدکننده­ی کارآمدی فانتوم ساده­ی طراحی شده همراه با دزیمترهای ترمولومینسانس، به عنوان یک سیستم مناسب برای مقایسه­ی متقابل دزیمتری در بین مراکز پرتودرمانی است.}, keywords_fa = {Quality Audit,Radiotherapy,Phantom,Ionization Chamber,Thermoluminescent Dosimetry,Quality Control,Photon Beams,Monte Carlo Method}, url = {https://jonsat.nstri.ir/article_408.html}, eprint = {https://jonsat.nstri.ir/article_408_23b785977bdb3a261899ffca06248efb.pdf} } @article { author = {Jabbari, I and Shahriari, M and Aghamiri, S.M.R and Monadi, SH}, title = {Introducing a Method to Derive a Multiple Virtual Point Source Model of Linac for Photon Beam Dose Calculation Using Monte Carlo Method}, journal = {Journal of Nuclear Science and Technology (JONSAT)}, volume = {32}, number = {3}, pages = {29-35}, year = {2011}, publisher = {Nuclear Science and Technology Research Institute}, issn = {1735-1871}, eissn = {2676-5861}, doi = {}, abstract = {In this study a new simple but a very effective method is introduced for the beam modeling of the invariant part of a medical linear accelerator. In this method, instead of segmentation of scoring plane and analysis of phase space file, the mirror image of a virtual point source, energy and angular distributions and dependencies between them are derived, directly. Then, the method was used for the beam modeling of a 6MeV photon beam of the Siemens ONCOR Impression accelerator, where the TALLYX capability of MCNP4C was used. Consequently, a multiple point source model with angular dependent photon energy spectra was obtained. Then, the percentage depth dose curves and the lateral dose distributions in water phantom were calculated using the present model for three field sizes including 4cm×4cm, 10cm×10cm and 40cm×40cm, and the results were compared to those of full Monte Carlo simulations. The results showed excellent agreement between them for all the field sizes. The benefits ofthe present method were verified as comparedwiththephasespacefileanalysismethod,including the easeofapplicationand the errors removal caused by the spatial segmentation of the phase space data.}, keywords = {Monte Carlo Simulation,MCNP,Photon Beam Modeling,Medical Linear Accelerator}, title_fa = {ارایه‌ی روشی مناسب برای مدل‌سازی چشمه‌ی مجازی چند نقطه‌ای شتاب‌دهنده‌ی خطی پزشکی در محاسبات دز فوتون به روش مونت‌کارلو}, abstract_fa = {در این تحقیق روشی جدید و ساده اما مؤثر برای مدل‌سازی بخش ثابت سر شتاب­دهنده­ی پزشکی ارایه شده است. در این روش به جای تقسیم­بندی مکانی و تجزیه و تحلیل اطلاعات فضای فاز ذخیره شده، تصویر آینه‌ای چشمه‌های مجازی نقطه‌ای، توزیع انرژی و زاویه‌ای فوتون‌ها و وابستگی آن­ها به یک­دیگر مستقیماً به دست می‌آید. این روش برای مدل­سازی باریکه­ی فوتونی MeV6 شتاب­دهنده­ی زیمنس (مدل ONCOR Impression) به کار گرفته شد و برای اجرای آن از قابلیت TALLYX کد MCNP4C استفاده گردید. در نتیجه مدل چشمه­ی چندنقطه‌ای با توزیع انرژی وابسته به زاویه به دست آمد. سپس با استفاده از مدل مجازی چشمه­ی به دست آمده، منحنی‌های درصد دز عمقی و توزیع‌های عرضی دز در فانتوم آب برای میدان‌های تابشی cm4×cm4، cm10×cm10 و cm40×cm40 محاسبه و نتایج حاصله با نتایج به دست آمده از شبیه‌سازی کامل مونت­کارلو، مقایسه شد. این، نشان داد که توافق بسیار خوبی بین این دو در تمام ابعاد میدان تابشی وجود دارد. از مزایای این روش در مقایسه با روش تجزیه و تحلیل اطلاعات فضای فاز، سهولت کاربرد و حذف خطای ناشی از ابعاد تقسیم­بندی مکانی اطلاعات فضای فاز است.}, keywords_fa = {Monte Carlo Simulation,MCNP,Photon Beam Modeling,Medical Linear Accelerator}, url = {https://jonsat.nstri.ir/article_409.html}, eprint = {https://jonsat.nstri.ir/article_409_28f71cad69c979e1beaacb3e5836cd67.pdf} } @article { author = {Faghihian, H and Seeidbagheri, A}, title = {Application of Cu-Tetraporphyrin Encapsulated in Zeolite as an Ion Exchanger for Removal of UO22+}, journal = {Journal of Nuclear Science and Technology (JONSAT)}, volume = {32}, number = {3}, pages = {36-45}, year = {2011}, publisher = {Nuclear Science and Technology Research Institute}, issn = {1735-1871}, eissn = {2676-5861}, doi = {}, abstract = {Uranium as a radioactive element is 500 times more abundant than gold and is widespreaded over the earth´s crust. The toxicity of uranium is much higher than its radioactivity. The removal of uranium from industrial and nuclear wastes is therefore an essential task. In this research, Zeolite Y was first synthesized and copper-tetraporphyrine was encapsulated in it’s pores. The adsorbent was characterized by different techniques including FT-IR, TG and UV-Vis spectroscopy. The adsorption of the studied cation was investigated at different experimental conditions. The effect of pH, initial concentration, time and temperature on the adsorption process was studied and optimized. The results showed that the adsorbent is a good candidate for the removal of the studied cation.}, keywords = {Zeolite,Porphyrine,Encapsulation,Ion Exchange,UO22+}, title_fa = {سنتز جاذب تترافنیل پورفیرین مس به دام افتاده در زئولیت به عنوان تبادل‌گر یون برای جذب یون‌های +22UO از محیط‌های آبی}, abstract_fa = {با توجه به خطرات اورانیم و لزوم حذف آن از پساب­های صنعتی و هسته­ای، در این مقاله، تترافنیل پورفیرین مس به دام افتاده در زئولیت Y به عنوان یک تبادل­گر یونی برای جذب +22UO مورد بررسی قرار گرفته شده است. ابتدا زئولیت Y سنتز و تترافنیل پورفیرین مس در حفرات بزرگ آن به دام انداخته شد. این ترکیب به کمک روش­های مختلف شامل پراش پرتو ایکس (XRD)، طیف­بینی تبدیل فوریه­ی زیر قرمز (FT-IR)، تجزیه­ی گرماگرانی­سنجی (TGA)، تجزیه­ی گرمایی تفاضلی (DTG) و نیز طیف­بینی فرابنفش- مرئی (UV-Vis) جامد شناسایی شد. سپس تأثیر عوامل مختلفی چون pH، غلظت محلول، زمان و دما بر روی میزان جذب یون­های +22UO بررسی گردید. تأثیر عوامل فوق بر میزان جذب با استفاده از روش عیارسنجی وانادومتری و طیف­سنجی جذب اتمی مطالعه شد. نتیجه­ی آزمایش­ها حاکی از آن است که جاذب، از ظرفیت جذب خوبی برای جذب کاتیون مورد بررسی برخوردار است.}, keywords_fa = {Zeolite,Porphyrine,Encapsulation,Ion Exchange,UO22+}, url = {https://jonsat.nstri.ir/article_410.html}, eprint = {https://jonsat.nstri.ir/article_410_56b4621156ab4d11e70df4e99790c5b6.pdf} } @article { author = {Damide, V and Sadighzadeh, A and Abdollahi, N and Koohi, A and Heidarnia, A and Aslezaeem, A.R and Bagheri, A and Khademzadeh, S and Kazemizadeh, F and Mehdipour, H and Sedaghat, M and Torabi, M and Kabir, M}, title = {Design and Construction of Inertial Electrostatic Confinement Fusion Device (IECF)}, journal = {Journal of Nuclear Science and Technology (JONSAT)}, volume = {32}, number = {3}, pages = {46-50}, year = {2011}, publisher = {Nuclear Science and Technology Research Institute}, issn = {1735-1871}, eissn = {2676-5861}, doi = {}, abstract = {In this paper, design and construction of an IECF device which produces continuous neutron flux by the inertial electrostatic confinement fusion is reported. The device is a stainless steel cylindrical chamber of 60cm in height and 60cm in diameter. Inside the chamber two concentric stainless steel-made spherical electrodes of 13.5cm and 41cm in diameter were installed. At a deutron gas pressure in the range of 10-3 to 10-2 mbar a condensed plasma during the electric discharge at the central part of two sphere was observed due to the D-D fusion reaction. By using a neutron track detector and a GM counter covered by indium foil, a neutron flux of more than 106 n/S was recorded. In this respect, a neutron dose rate of 100μSv/h by the use of LB6411 neutron dosimeter was also detected.}, keywords = {Nuclear fusion,Electric Glow Discharge,Neutron Genarater,Inertial Electrostatic Confinement}, title_fa = {طراحی و ساخت دستگاه هم‌جوشی هسته‌ای به روش محصورسازی الکتروستاتیکی جرمی (IECF)}, abstract_fa = {در این مقاله، به طراحی و ساخت دستگاه هم­جوشی به روش محصورسازی الکترواستاتیکی جرمی، که شار نوترونی پیوسته­ی آن به روش محصورسازی الکتروستاتیکی جرمی تولید می­شود، پرداخته شده است. این دستگاه از یک محفظه­ی خلاء استوانه­ای شکل از جنس فولاد ضدزنگ به قطر و ارتفاع 60 سانتی­متر ساخته شده است. در داخل این محفظه، دو الکترود کروی هم مرکز از جنس فولاد ضدزنگ به قطرهای 13.5cm و 41 سانتی­متر قرار دارد. در اثر تخلیه­ی الکتریکی در گاز دوتریم در محدوده­ی فشاری 2-10 تا 3-10 میلی­بار، پلاسمای چگال تشکیل شده در ناحیه­ی مرکز دو کره کاملاً قابل مشاهده است. با تزریق گاز دوتریم به درون این دستگاه، واکنش هم­جوشی D-D انجام می­گیرد. آشکارسازهای گایگر با پوشش ایندیم، آشکارساز ردپای نوترون و II Neutron RAE در هر ثانیه به طور متوسط بیش از 106 نوترون برثانیه را ثبت کردند. هم­چنین دز نوترونی μSv/h100 با استفاده از دزیمتر LB6411 اندازه­گیری شد.}, keywords_fa = {Nuclear fusion,Electric Glow Discharge,Neutron Genarater,Inertial Electrostatic Confinement}, url = {https://jonsat.nstri.ir/article_411.html}, eprint = {https://jonsat.nstri.ir/article_411_46d4edf61e94ee6b8ec8aacf524cb5c6.pdf} } @article { author = {Rahighi, J and Jafarzadeh Khatibani, M and Sadati, S.M and Ghods, H}, title = {Construction of the 150kV Electrostatic Accelerator Tube}, journal = {Journal of Nuclear Science and Technology (JONSAT)}, volume = {32}, number = {3}, pages = {51-58}, year = {2011}, publisher = {Nuclear Science and Technology Research Institute}, issn = {1735-1871}, eissn = {2676-5861}, doi = {}, abstract = {An electrostatic accelerator tube capable of accelerating proton, deuteron, alpha beam and heavier ions up to an energy of 150keV has been designed and constructed. This tube can be operated with a Cockroft-Walton type high voltage generator. The construction of the tube is important from two different standpoints. First, because it will initiate the use of low energy accelerators for both scientific and industrial development in country and also this step will lead the country toward approaching the accelerator design technology, an issue which has been severely overlooked for the past few decades. The present accelerator tube consists of 11 different electrodes forming 3 cylindrical lenses, i.e., extractor lens, focusing lens and cooling lens. An accelerator column which includes 7 collimating lenses follows the cooling lens. The tube can accelerate 2H+ up to an energy of 150keV. The accelerator column was successfully tested for the high vacuum and the voltage up to 150kV. A radio frequency type ion source was used to check the performance of the tube. Measurements demonstrated that a beam current close to 850µA can be readily obtained in the present system.}, keywords = {Accelerator Tube,Electrostatic accelerator,Electrostatic Lenses,SIMION,Superfish,Ion Optics}, title_fa = {ساخت ستون شتاب‌دهنده‌ی الکترواستاتیکی kV150}, abstract_fa = {یک ستون شتاب­دهنده­ی الکترواستاتیکی برای تولید باریکه­های پروتون، دوترون، آلفا و یون­های سنگین­تر با انرژی keV150 طراحی و ساخته شده است. این ستون شتاب­دهنده را می­توان همراه با یک مولد ولتاژ بالا از نوع کاک­کرافت والتون مورد استفاده قرار داد. ساخت این ستون شتاب­دهنده قدم مهمی در به دست آوردن فن­آوری طراحی و ساخت شتاب­دهنده در کشور است. در ساخت این ستون 11 الکترود فلزی با شکل­های گوناگون به کار رفته است که شامل سه عدسی استوانه­ای تولید کننده­ی باریکه، عدسی کانونی­کننده­ی باریکه، عدسی خنک­کننده­ی باریکه و یک کانال شتاب­دهنده با هفت عدسی دهانه­ای است. آزمایش­ها و اندازه­گیری­های انجام شده با استفاده از یک چشمه­ی یونی از نوع بسامد رادیویی نشان داد که این ستون قادر است جریانی در حدود Aμ850 را با انرژی keV150 به هدف بتاباند.}, keywords_fa = {Accelerator Tube,Electrostatic accelerator,Electrostatic Lenses,SIMION,Superfish,Ion Optics}, url = {https://jonsat.nstri.ir/article_412.html}, eprint = {https://jonsat.nstri.ir/article_412_2e8bf8b22a6a9821c0662a374748a900.pdf} } @article { author = {A. Milani, S and Sam, A}, title = {Alkaline Autoclave Leaching of Refractory Uranium-Thorium Minerals}, journal = {Journal of Nuclear Science and Technology (JONSAT)}, volume = {32}, number = {3}, pages = {59-67}, year = {2011}, publisher = {Nuclear Science and Technology Research Institute}, issn = {1735-1871}, eissn = {2676-5861}, doi = {}, abstract = {This paper deals a with the study of an innovative method for processing the Oman placer ores by alkaline leaching in ball mill autoclaves, where grinding and leaching of the refractory minerals take place simultaneously. This was followed by the selective separation of thorium and uranium from lanthanides by autoclave leaching of the hydroxide cake with ammonium carbonate-bicarbonate solutions. The introduced method is based on the fact that thorium and uranium form soluble carbonate complexes with ammonium carbonate, while lanthanides form sparingly soluble double carbonates. It was found that a complete alkaline leaching of Oman placer ores (98.0%) was attained at 150 and 175°C within 2.5 and 2h, respectively. Oman placer ores leaching was intensified and accelerated in a ball mill autoclaves as a result of the grinding action of steel balls, removal of the hydroxide layer covering ores grains and the continuous contact of fresh ore grains with alkaline solution. The study of selective carbonate processing of hydroxide cake with ammonium carbonate-bicarbonate solutions on autoclave under pressure revealed that the complete thorium recovery (97.5%) with uranium recovery (90.8%) and their separation from the lanthanides were attained at 70-80°C during 1-2h. The extraction of  lanthanides in carbonate solution was low and did not exceed 4.6%.}, keywords = {Alkaline Autoclave Leaching,Uranium-Thorium Refractory Minerals,Ball Mill Autoclave,Oman Placer}, title_fa = {فروشویی قلیایی- اتوکلاوی کانی‌های مقاوم اورانیم- توریم}, abstract_fa = {این مقاله­ به مطالعه و بررسی یک روش نوآورانه برای فرآوری کانی­های مقاوم ماسه­های ساحلی دریای عمان از طریق فروشویی قلیایی در اتوکلاو آسیای گلوله­ای، که در آن خردایش و فروشویی کانی­ها به طور هم­زمان انجام می­شود، می­پردازد. این مطالعه با جداسازی انتخابی توریم و اورانیم از طریق فروشویی اتوکلاوی کیک هیدروکسید حاصل، با محلول­های آمونیم کربنات- بی­کربنات ادامه می­یابد. این روش بر مبنای این حقیقت استوار است که توریم و اورانیم با آمونیم کربنات کمپلکس­های کربنات محلول تشکیل می­دهند، در حالی که لانتانیدها، کربنات­های مضاعف کم محلول پدید می­آورند. فروشویی کامل(98.0%)  کنسانتره­ی کانی­های سنگین و مقاوم حاصل از فرآوری فیزیکی ماسه­های ساحلی دریای عمان در 150 و °C175، ظرف مدت، به ترتیب، 2.5  و 2 ساعت حاصل شد که طی آن کیک هیدروکسید عناصر اورانیم، توریم و خاکی­های نادر تولید گردید. عملیات فروشویی در اتوکلاو آسیا­ی گلوله­ای در نتیجه­­ی عمل خردایشیگلوله­های فولادی، برداشت مداوم لایه­ی هیدروکسید از سطوح ذرات تحت واکنش، و تماس مداوم سطح کانی با محلول قلیایی تسریع و تشدید گردید. مطالعه­ی فروشویی کربناته­ی انتخابی تحت فشار کیک هیدروکسید با محلول­های کربنات- بی­کربنات در اتوکلاو نشان داد که بازیابی کامل توریم(97.5%)  همراه با بازیابی اورانیم(90.8%)  و جداسازی آن­ها از لانتانیدها در دمای 70 تا °C80 و در مدت 1 تا 2 ساعت به انجام رسید. میزان استخراج لانتانیدها به درون محلول کربنات ناچیز بوده و به طور متوسط از 4.6% فراتر نرفت.}, keywords_fa = {Alkaline Autoclave Leaching,Uranium-Thorium Refractory Minerals,Ball Mill Autoclave,Oman Placer}, url = {https://jonsat.nstri.ir/article_413.html}, eprint = {https://jonsat.nstri.ir/article_413_b23d40f3c23fe0100ff4218d4a89db31.pdf} }