In cooperation with the Iranian Nuclear Society

Document Type : Scientific Note

Authors

1 Faculty of Physics, University of Isfahan, P.O. Box: 81746-73441, Isfahan - Iran

2 Plasma and Nuclear Fusion Research School, Nuclear Science and Technology Research Institute, AEOI, P.O. Box: 14155-1339, Tehran - Iran

Abstract

Plasma impurities are one of the loss factors of confined energy in tokamaks, so from this regard their study in order to maintain the stability of tokamak plasma and improve the confinement quality is essential. In this research, in order to study the impurities of Damavand tokamak plasma, a monochromator along with a Line Scan CCD array in the assembly of a visible light spectrometer was used. The modified spectrometer system was calibrated by the characteristic wavelengths of a mercury-vapor lamp and was used in the normal plasma regime of Damavand tokamak to record and analyze the radiation in the wavelength range of 3000-7000A°. The finest instrumental resolution of the spectrometer was about 0.9A° at entrance slit width of 50μm, which was used for intensive hydrogen plasma radiation lines such as Hα and Hβ. To study the radiation from the impurities, due to their low intensity, the entrance slit width of 100 μm and the resolution of 1.8A° were selected. The results showed that the predominant impurities in Damavand tokamak plasma are oxygen, nitrogen and carbon, which are generally originated from air molecules trapped in the wall of the vacuum chamber and the plasma facing components, also iron impurities are produced as a result of hot plasma interaction with the limiter and other components inside the vacuum chamber.

Keywords

1. G.G. Dolgov-Saveljev, et al, Toroidal discharge in a strong magnetic field, Soviet Phys.—JETP, 11, 287 (1960).
 
2. V.S. Strelkov, History of T-10 tokamak: creation and development, Plasma Phys. Rep., 27, 819 (2001).
 
3. V.P. Smirnov, Tokamak foundation in USSR/Russia 1950–1990, Nucl. Fusion, 50, 014003 (2010).
 
4. H.R. Koslowski, Operational Limits and Limiting Instabilities in Tokamak MachinesFusion Science and Technology, 49(2T), 147 (2006).
 
5. D.E. Post, et al., Steady-state radiative cooling rates for low-density high-temperature plasmas, At. Data Nucl. Data Tables, 20, 397 (1977).
 
6. FU. Jia, et al., Spectroscopic Measurements of Impurity Spectra on the EAST tokamak, Plasma Science and Technology, 14, 1048 (2012).
 
7. A. Gorbunov, L.A. Klyuchnikov, K.V. Korobov, Visible range spectrum of the T-10 tokamak plasma, ВАНТ. Сер. Термоядерный синтез, 38, 62, (2015).
 
8. A.M. Dalt Rini, M. Machida, M.J.R. Moterio, Vacuum Ultraviolet and Visible Spectroscopy Diagnostics on the NOVA-UNICAMP tokamak, Brazilian Journal of Physics, 31, 496 (2001).
 
9. H. Mohammadi, E. Eslami, Investigation of Spectral Resolution in a Czerny Turner Spectrograph, Instruments and Experimental Techniques, 53, 549, (2010).
 
10. Liu, Chuan; Berg, Rolf W., Determining the Spectral Resolution of a Charge-Coupled Device (CCD) Raman Instrument, Applied Spectroscopy, 66, 1034 (2012).