نوع مقاله : مقاله پژوهشی
نویسندگان
1 گروه فیزیک پزشکی، دانشکده علوم پزشکی، دانشگاه تربیت مدرس، صندوق پستی: 151-14115، تهران- ایران
2 انستیتو پرتو پزشکی نوین، صندوق پستی: 1466643691، تهران- ایران
3 گروه پرتو پزشکی، دانشکده علوم هستهای، دانشگاه شهید بهشتی، صندوق پستی: 1983963113، تهران- ایران
4 گروه فیزیک پزشکی، دانشکده پزشکی، دانشگاه علوم پزشکی ایران، صندوق پستی: 141555983، تهران- ایران
کلیدواژهها
عنوان مقاله English
نویسندگان English
Recent advances in radiation therapy have made obvious the need for dosimeters that can measure three-dimensional (3-D) dose distributions. Currently, radiosensitive gel dosimeters have provided 3-D dose measurements using the MRI technique. However, this method has some limitations. Recently, a novel transparent polymer dosimeter, PRESAGE, has been introduced which exhibits a radiochromic response when exposed to ionizing radiation. This dosimetry technique has some advantages compared with other gel dosimeters. In this study, the dose response, linearity, sensitivity, and stability of this type of dosimeter were investigated for different levels of the activator, and leuco dye concentration. In this regard, the PRESAGE dosimeters were made with different formulations and were irradiated by gamma-rays of Cobalt-60 in the dose range of 0-50 Gy. Then, the optical absorption changes of the dosimeters were measured by a spectrophotometer over a period of 14 days after the irradiation. The results indicated that increasing the activator concentration leads to the increase of the sensitivity, but decreases the stability of the dosimeter response. Furthermore, it was noted that the dosimeter shows a linear response to the radiation dose with a high level of correlation (R2>0.99).
کلیدواژهها English
10. Y. De Deene, K. Vergote, C. Claeys, C. De Wagter, “The fundamental radiation properties of normoxic polymer gel dosimeters: a comparison between a methacrylic acid based gel and acrylamide based gels,” Phys. Med. Biol. 51, 653–673 (2006).
11. J. Adamovics, M.J. Maryanski, “A new approach to radiochromic three-dimensional dosimetry-polyurethane,” Third International Conference on Radiotherapy Gel Dosimetry, Journal of Physics, Conference Series 3, 172–175 (2004).
12. P.Y. Guo, J. Adamovics, M. Oldham, “Characterization of a new radiochromic three-dimensional dosimeter,” Med. Phys. 33, 1338-1345 (2006).
13. J. Adamovics, M.J. Maryanski, “Characterization of PRESAGE: a new 3-D radiochromic solid polymer dosimeter for ionizing radiation,” Radiat. Prot. Dosim. 120, 107–112 (2006).